Re-enable a webhook after repeated failures
Repair and test an auto-disabled webhook receiver before re-enabling it, then replay only the failed events the downstream system still needs.
Last reviewed
Dosya auto-disables a webhook after 15 consecutive failed delivery attempts. Prove the receiver first: the test route can call a disabled endpoint without reopening normal event traffic.

Steps
- Open Integrations → Webhooks in the affected workspace and find the Disabled card with Auto-disabled after repeated failures. Note the reported failure count and disable time.
- Repair DNS, TLS, routing, signature verification, durable queueing, and the response path. The URL must remain public HTTPS, and the receiver must answer with 2xx within ten seconds.
- Select Send test event while the endpoint is still disabled. Dosya creates a signed
file.uploadedsample and reports Test event sent — Check the deliveries log below for the result. - Open Deliveries and wait for that new row to show Success. The toast proves creation only; Pending, Failed,
Error, or a non-2xx response means the receiver is not ready. - Select Re-enable. The server sets the endpoint active, clears
consecutive_failures, removesdisabled_at, and reports Webhook re-enabled. - Trigger one controlled subscribed event and verify another Success. Review older Failed rows separately because activation does not resurrect or replay them.
The failure threshold counts attempts across the endpoint, so several broken events can reach 15 before one event exhausts its own six attempts. A successful test clears the active failure incident but does not itself set the disabled endpoint active.

Expected result
The receiver proves a successful signed request before future traffic resumes. The endpoint returns to Active with cleared failure state, and only explicitly redelivered historical events run again.
Re-enable failed leaves the endpoint disabled. Reload the card, confirm the role still has manage_settings, and retry without repeatedly sending tests.
The endpoint disables again. Inspect the most recent response status or transport error and stop re-enabling until the underlying receiver failure is corrected.
Related guides
Was this helpful?
Loading helpfulness results…
Voting saves a necessary ballot cookie for up to 180 days so you can change your answer.
Questions and replies
Ask about the steps in this guide. Questions are reviewed before publication.
Keep account details, credentials and private files out of public questions. Use private support for those.
Loading questions…
Sign in to your Dosya account to ask a question.